184 research outputs found

    Investigating the effect of urgency and modality of pedestrian alert warnings on driver acceptance and performance

    Get PDF
    Active safety systems have the potential to reduce the risk to pedestrians by warning the driver and/or taking evasive action to reduce the effects of or avoid a collision. However, current systems are limited in the range of scenarios they can address using primary control interventions, and this arguably places more emphasis in some situations on warning the driver so that they can take appropriate action in response to pedestrian hazards. In a counterbalanced experimental design, we varied urgency (‘when’) based on the time-to-collision (TTC) at which the warning was presented (with associated false-positive alarms, but no false negatives, or ‘misses’), and modality (‘how’) by presenting warnings using audio-only and audio combined with visual alerts presented on a HUD. Results from 24 experienced drivers, who negotiated an urban scenario during twelve 6.0-minute drives in a medium-fidelity driving simulator, showed that all warnings were generally rated ‘positively’ (using recognised subjective ‘acceptance’ scales), although acceptance was lower when warnings were delivered at the shortest (2.0s) TTC. In addition, drivers indicated higher confidence in combined audio and visual warnings in all situations. Performance (based on safety margins associated with critical events) varied significantly between warning onset times, with drivers first fixating their gaze on the hazard, taking their foot off the accelerator, applying their foot on the brake, and ultimately bringing the car to a stop further from the pedestrian when warnings were presented at the longest (5.0s) TTC. In addition, drivers applied the brake further from the pedestrian when combined audio and HUD warnings were provided (compared to audio-only), but only at 5.0s TTC. Overall, the study indicates a greater margin of safety associated with the provision of earlier warnings, with no apparent detriment to acceptance, despite relatively high false alarm rates at longer TTCs. Also, that drivers feel more confident with a warning system present, especially when it incorporates auditory and visual elements, even though the visual cue does not necessarily improve hazard localisation or driving performance beyond the advantages offered by auditory alerts alone. Findings are discussed in the context of the design, evaluation and acceptance of active safety systems

    A Perceptual Color-Matching Method for Examining Color Blending in Augmented Reality Head-Up Display Graphics

    Get PDF
    Augmented reality (AR) offers new ways to visualize information on-the-go. As noted in related work, AR graphics presented via optical see-through AR displays are particularly prone to color blending, whereby intended graphic colors may be perceptually altered by real-world backgrounds, ultimately degrading usability. This work adds to this body of knowledge by presenting a methodology for assessing AR interface color robustness, as quantitatively measured via shifts in the CIE color space, and qualitatively assessed in terms of users’ perceived color name. We conducted a human factors study where twelve participants examined eight AR colors atop three real-world backgrounds as viewed through an in-vehicle AR head-up display (HUD); a type of optical see-through display used to project driving-related information atop the forward-looking road scene. Participants completed visual search tasks, matched the perceived AR HUD color against the WCS color palette, and verbally named the perceived color. We present analysis that suggests blue, green, and yellow AR colors are relatively robust, while red and brown are not, and discuss the impact of chromaticity shift and dispersion on outdoor AR interface design. While this work presents a case study in transportation, the methodology is applicable to a wide range of AR displays in many application domains and settings

    Calibration of the Logarithmic-Periodic Dipole Antenna (LPDA) Radio Stations at the Pierre Auger Observatory using an Octocopter

    Get PDF
    An in-situ calibration of a logarithmic periodic dipole antenna with a frequency coverage of 30 MHz to 80 MHz is performed. Such antennas are part of a radio station system used for detection of cosmic ray induced air showers at the Engineering Radio Array of the Pierre Auger Observatory, the so-called Auger Engineering Radio Array (AERA). The directional and frequency characteristics of the broadband antenna are investigated using a remotely piloted aircraft (RPA) carrying a small transmitting antenna. The antenna sensitivity is described by the vector effective length relating the measured voltage with the electric-field components perpendicular to the incoming signal direction. The horizontal and meridional components are determined with an overall uncertainty of 7.4^{+0.9}_{-0.3} % and 10.3^{+2.8}_{-1.7} % respectively. The measurement is used to correct a simulated response of the frequency and directional response of the antenna. In addition, the influence of the ground conductivity and permittivity on the antenna response is simulated. Both have a negligible influence given the ground conditions measured at the detector site. The overall uncertainties of the vector effective length components result in an uncertainty of 8.8^{+2.1}_{-1.3} % in the square root of the energy fluence for incoming signal directions with zenith angles smaller than 60{\deg}.Comment: Published version. Updated online abstract only. Manuscript is unchanged with respect to v2. 39 pages, 15 figures, 2 table

    Design and implementation of the AMIGA embedded system for data acquisition

    Get PDF

    The energy spectrum of cosmic rays beyond the turn-down around 10^17 eV as measured with the surface detector of the Pierre Auger Observatory

    Get PDF
    We present a measurement of the cosmic-ray spectrum above 100 PeV using the part of the surface detector of the Pierre Auger Observatory that has a spacing of 750 m. An inflection of the spectrum is observed, confirming the presence of the so-called second-knee feature. The spectrum is then combined with that of the 1500 m array to produce a single measurement of the flux, linking this spectral feature with the three additional breaks at the highest energies. The combined spectrum, with an energy scale set calorimetrically via fluorescence telescopes and using a single detector type, results in the most statistically and systematically precise measurement of spectral breaks yet obtained. These measurements are critical for furthering our understanding of the highest energy cosmic rays

    Direct measurement of the muonic content of extensive air showers between 2×1017\mathbf { 2\times 10^{17}} and 2×1018 \mathbf {2\times 10^{18}}~eV at the Pierre Auger Observatory

    Get PDF
    The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between 2×1017^{17} and 2×1018^{18} eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at 1017.5^{17.5}eV and 1018^{18}eV. We find that, for the models to explain the data, an increase in the muon density of 38% ±4%(12%) ± (21%)Š(18%) for EPOS-LHC, and of 50%(53%) ±4%(13%) ± (23%)Š(20%) for QGSJetII-04, is respectively needed

    First results from the AugerPrime Radio Detector

    Get PDF

    Update of the Offline Framework for AugerPrime

    Get PDF

    Performance of the 433 m surface array of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory, located in western Argentina, is the world’s largest cosmic-ray observatory. While it was originally built to study the cosmic-ray flux above 1018.5 eV, several enhancements have reduced this energy threshold. One such enhancement is a surface array composed of a triangular grid of 19 water-Cherenkov detectors separated by 433 m (SD-433) to explore the energies down to about 1016 eV. We are developing two research lines employing the SD-433. Firstly, we will measure the energy spectrum in a region where previous experiments have shown evidence of the second knee. Secondly, we will search for ultra-high energy photons to study PeV cosmic-ray sources residing in the Galactic center. In this work, we introduce the SD-433 and we show that it is fully efficient above 5×1016 eV for hadronic primaries with ξ < 45°. Using seven years of data, we present the parametrization of the lateral distribution function of measured signals. Finally, we show that an angular resolution of 1.8° (0.5°) can be attained at the lowest (highest) primary energies. Our study lays the goundmark for measurements in the energy range above 1016 eV by utilizing the SD-433 and thus expanding the scientific output of the Auger surface detector
    • 

    corecore